WGT-1000 Wireless Online Single Glove Integrity Tester Specification

  • Specimen Size
  • Standard glove ports
  • Interface Type
  • Wireless, USB
  • Display Type
  • Digital LCD touchscreen
  • Hardness
  • N/A (not applicable)
  • Features
  • Wireless operation, automatic data logging, rapid leak detection, easy mounting and removal
  • Mounting Type
  • Clamp or flange mounting
  • Automation Grade
  • Fully automatic
  • Temperature
  • 10C~40C
  • Resolution
  • 0.01 ml/min
  • Gas Pressure
  • 0.4~0.6 MPa
  • Accuracy
  • 0.1 ml/min
  • Response Time
  • 3 seconds
  • Test Range
  • 0~1000 ml/min leakage
  • Power Supply
  • AC 220V, 50Hz
  • Measuring Range
  • 0.1~1000 ml/min
  • Application
  • Glove leak/air tightness testing in isolators, RABS, and gloveboxes
  • Number of Specimens
  • 1 glove
  • Frequency
  • 50 Hz
  • Humidity
  • 10%~90% RH
  • Port Size
  • Standard (customizable available)
  • Equipment Type
  • Online Glove Integrity Tester
  • Operating Voltage
  • 220VAC
  • Max Height
  • 400 mm (including mounting)
  • Usage
  • Online glove integrity/leak testing
  • Capacity
  • Single glove station
  • Machine Weight
  • 15 kg
  • Test Speed
  • Adjustable (per user requirement)
  • Test Width
  • 250 mm
  • Test Stroke
  • Standard 350 mm
  • Control Mode
  • Wireless remote control
  • Battery Backup
  • Up to 2 hours operation (optional)
  • Calibration
  • Factory calibrated, user calibration optional
  • Memory Storage
  • Internal log up to 500 test records
  • Data Output
  • Exportable via USB or wireless connection
  • Compliance
  • Meets ISO 14644-7 and GMP guidelines
  • Alarm System
  • Visual and audible alarm for failed tests
  • Material of Construction
  • Stainless steel body with polycarbonate housing
  • Language Support
  • Multi-language (English/Chinese/German)
  • Protection Class
  • IP54
  • Communication Protocol
  • Wi-Fi 802.11b/g/n
 
 

About WGT-1000 Wireless Online Single Glove Integrity Tester

Instrument characteristics:

  • It is connected to the PC wirelessly via WIFI, and the detection data can be transmitted wirelessly.
  • Supporting powerful upper computer management software, which can manage multiple detection units at the same time.
  • RFID chip technology, automatic identification of glove number, included in the test result.
  • Meet the IP65 protection level, which is convenient for disinfection and cleaning of equipment.
  • There are multiple program settings to meet the testing requirements of gloves of different specifications and materials.
  • The pressure detection range can reach 3000Pa, covering all glove detection pressures.
  • Automatically monitor the pressure in the inflatable sealing ring and the glove during the test.
  • The instrument uses a small amount of frequent air intake, and the air intake speed in the glove is uniform to avoid deformation of the glove.
  • Color touch screen, user-friendly interface design, and can automatically select and match the testing program that best suits the current glove according to different test parameters, and display the date and time.
  • Easy to move, easy to carry, fast connection.
  • Historical records can be transmitted, stored, and inquired.
  • According to customer needs, we can customize pallets of different sizes to achieve multiple pallet operations on one machine.
  • Comply with FDA/GMP and other regulations and computer system verification requirements.
  • The software complies with 21CFR part11 electronic records and electronic signature certification requirements.

Application field:

  • Pharmaceutical industry: sterile inspection and microbial limit inspection of purified water, water for injection, sterile preparations (large infusion, small injection, powder, biological products, blood products, ophthalmic preparations, maintenance solutions, etc.).
  • Medical equipment industry: sterility inspection and microbial limit inspection of purified water, water for injection, syringes, infusion sets, blood transfusion sets, intravenous catheters, etc.
  • Food and beverage industry.
  • Environmental protection industry, etc.



Reliable Online Glove Leak Testing

Detect glove integrity issues quickly with the WGT-1000 tester, designed for single-glove stations in isolators and RABS. Its rapid, wireless-controlled operation and easy mounting options cater to high-demand environments, providing efficient protection for product and personnel safety.


Compliant and Versatile Design

Fully meeting ISO 14644-7 and GMP guidelines, the WGT-1000 delivers reliable test results across various industries. The robust stainless steel body with IP54 protection, a digital LCD touchscreen, and the flexibility to export data wirelessly or via USB make it suitable for both manufacturers and quality assurance labs.

FAQ's of WGT-1000 Wireless Online Single Glove Integrity Tester:


Q: How does the WGT-1000 Glove Integrity Tester operate?

A: The WGT-1000 uses a fully automatic process to test a single glove's airtightness by applying controlled gas pressure and monitoring for leakage. It is operated wirelessly via remote control and provides both visual and audible alarms for failed tests.

Q: What are the main benefits of using the WGT-1000 for glove leak testing?

A: Users benefit from rapid test speeds (response time 3 seconds), high accuracy (0.1 ml/min), and automatic data logging. Its compliance with ISO and GMP standards ensures reliable, traceable results for quality assurance.

Q: When should the Glove Integrity Tester be calibrated?

A: The device comes factory calibrated, but users can perform optional calibrations as needed based on company protocols or compliance requirements.

Q: Where can test data be accessed and exported from the device?

A: Test records, stored in the internal memory (up to 500 entries), can be exported via USB or wirelessly. The digital LCD touchscreen also allows for convenient on-site review.

Q: What is the typical process for mounting and using the WGT-1000?

A: Mount the device using clamp or flange options on the glove port, initiate the test wirelessly, and follow the on-screen prompts. The tester automatically logs results and issues alarms if leaks are detected.

Q: Can the tester accommodate different glove port sizes or types?

A: The WGT-1000 supports standard glove ports and also offers customizable port sizes to fit unique equipment needs, enhancing compatibility across applications.

Q: What environments is the WGT-1000 suitable for?

A: With IP54 protection, stainless steel construction, and an operating range of 10C-40C with up to 90% humidity, the WGT-1000 works well in diverse, critical cleanroom and manufacturing settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Glove Integrity Tester Category

WGT-1200 Wireless Online Multi Units Glove Integrity Tester

WGT-1200 Wireless Online Multi Units Glove Integrity Tester

Response Time : <1 second

Test Range : Room Pressure to 5000 Pa

Resolution : 1 Pa

Gas Pressure : 0.3 0.8 MPa (Compressed air)

Accuracy : 1% FS

Temperature : 10C 40C Operating Range

GT-2.0 Online Glove Integrity Tester

GT-2.0 Online Glove Integrity Tester

Response Time : 3 sec

Test Range : 10 Pa to 2000 Pa

Resolution : 0.1 Pa

Gas Pressure : 0.40.6 MPa

Accuracy : 1 Pa

Temperature : 1040C

GT-2.0 Offline Glove Leakage Tester

GT-2.0 Offline Glove Leakage Tester

Response Time : Immediate upon leakage detection

Test Range : Complete Finger and Palm Coverage

Resolution : Visual (0.1 mm minimal observable)

Gas Pressure : 0.10.3 MPa

Accuracy : Highly sensitive, detects leakage 0.5mm

Temperature : 545C

GT-3.0  Glove Integrity Tester Online

GT-3.0 Glove Integrity Tester Online

Response Time : < 3 seconds

Test Range : 1.0 micron 100 micron

Resolution : 0.01 microliters/min

Gas Pressure : 0.5 1.6 bar

Accuracy : 0.2 microliters/min

Temperature : 10C 40C



Back to top