7310 AeroTrak-Plus Remote Particle Counter
7310 AeroTrak-Plus Remote Particle Counter

7310 AeroTrak-Plus Remote Particle Counter

7310 AeroTrak-Plus Remote Particle Counter Specification

  • Application
  • Cleanroom monitoring, contamination control
  • Resolution
  • 0.1 m
  • Power Supply
  • 24 VDC, 1.25 A
  • Response Time
  • <1 minute to alarm
  • Interface Type
  • RS-485, Ethernet, Modbus TCP/IP
  • Automation Grade
  • Automatic
  • Test Range
  • 0.3 25 m (particle sizes)
  • Mounting Type
  • Wall-mounted or panel-mounted
  • Operating Voltage
  • 24 VDC
  • Features
  • Long-life laser diode, internal vacuum sensor, HEPA filtered exhaust, stainless steel enclosure
  • Temperature
  • 10C to 35C (operating)
  • Equipment Type
  • Remote Particle Counter
  • Measuring Range
  • 0.3 m, 0.5 m, 1.0 m, 5.0 m, 10.0 m, 25.0 m
  • Port Size
  • 1/4 or 6 mm ID
  • Gas Pressure
  • 0.70 to 2.75 bar (10 to 40 psi)
  • Accuracy
  • Meets ISO 21501-4 and JIS B9921
  • Humidity
  • 0 to 90% RH (non-condensing)
  • Display Type
  • N/A (Remote unit)
  • Usage
  • Continuous particle monitoring
  • Capacity
  • 10,000 sample records
  • Machine Weight
  • Approx. 2.2 kg
  • Test Speed
  • 0.1 CFM (2.83 LPM)
  • Control Mode
  • RS-485 / Modbus
 
 

About 7310 AeroTrak-Plus Remote Particle Counter

Features and Benefits

  • Easy installation and reliable operation with reduced costs
  • Reliable laser technology backed by the industrys longest warranty (five years)
  • Secure, long-term collection and storage of critical manufacturing data
  • Reduce installation costs and complexitywireless enabled with minimal infrastructure
  • Identifies industrys widest range of particle sizes by way of available model options
  • Simplifies integration with Ethernet or DC power
  • Reliable operation with heavy industrial electrical immunity compliance
  • Early-warning of adverse environmental trends with per second sampling
  • Predictive instrument maintenance alerts
  • ISO 14644-14 suitability for use classified
  • Sealed inlet prevents accidental ingress of cleaning solutions
  • Rapid setup and unit configuration using standard USB-C cable
  • Easy integration into TSI FMS Software with sensor auto discovery
  • Easy Integration into third party systems with 4-20 mA analog data output model options
  • Model 7510 only
  • Enables 21 CFR Part 11 data collection with FMS Software
  • Meets EU and US FDA Aseptic Processing Guidelines with 1 CFM (28.3 L/min) flow rate, 0.5 m and 5 m size channel size options
  • Vaporized hydrogen peroxide (VHP) resistant model option



Precision Contamination Monitoring

The 7310 AeroTrak-Plus Remote Particle Counter delivers highly accurate and automated measurement of airborne particles ranging from 0.3 to 25.0 m. Its compliance with ISO 21501-4, ISO 14644, and GMP guidelines makes it a reliable tool for maintaining cleanroom standards in pharmaceutical, semiconductor, and other sensitive industries.


Advanced Data Management and Integration

Equipped with 10,000-record storage capacity, this device offers seamless data export via Ethernet TCP/IP and RS-485 Modbus networks. Its flexible integration options allow for easy communication with building management systems and real-time monitoring through configurable alarms and notifications.


Robust Design for Demanding Environments

Encased in heavy-duty 316L stainless steel, the AeroTrak-Plus ensures durability and chemical resistance, critical for challenging cleanroom settings. The HEPA-filtered exhaust, internal vacuum sensor, and isokinetic probe provide safe, accurate, and reliable long-term monitoring.

FAQ's of 7310 AeroTrak-Plus Remote Particle Counter:


Q: How does the 7310 AeroTrak-Plus Remote Particle Counter operate in a cleanroom environment?

A: This counter uses an isokinetic probe for precise sampling and can be wall- or panel-mounted for seamless integration. It continuously monitors airborne particle levels and instantly triggers alarms if thresholds are exceeded, ensuring immediate response to contamination.

Q: What data output and integration options are available with this device?

A: The system provides data transmission via Ethernet TCP/IP, RS-485, and Modbus, allowing for compatibility with building management systems and remote notification setup. This supports comprehensive monitoring and traceability.

Q: Where is the AeroTrak-Plus Remote Particle Counter typically used?

A: It is designed primarily for cleanrooms and contamination-sensitive environments such as those found in pharmaceuticals, electronics manufacturing, hospitals, and research labs, where maintaining airborne particle levels is critical.

Q: What are the benefits of using a device with a long-life laser diode and stainless steel enclosure?

A: The long-life laser diode ensures consistent measurement accuracy for over 10 years with minimal maintenance, while the 316L stainless steel enclosure resists corrosion and withstands harsh cleaning procedures, maximizing operational lifespan.

Q: When can users access stored data on the particle counter?

A: The AeroTrak-Plus stores up to 10,000 data sets, which can be retrieved any time via its data interfaces. The information is available for audit, compliance, or trend analysis as needed by facility operations or regulatory requirements.

Q: What process does the device use for sampling and analysis?

A: The counter operates using continuous, timed, delay, or repeat sampling modes. It detects and sizes particles from 0.3 to 25.0 m with an accuracy that meets ISO 21501-4 and JIS B9921, ensuring robust contamination control.

Q: How quickly does the device respond to particulate events?

A: With a response time of less than one minute to trigger alarms, the AeroTrak-Plus provides near-instantaneous alerts for out-of-spec conditions, allowing for rapid intervention to protect cleanroom integrity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Online Particle Counter Category

7201 AeroTrak-Plus Remote Particle Counter

7201 AeroTrak-Plus Remote Particle Counter

Humidity : 0 to 95% RH (noncondensing)

Accuracy : Compliant with ISO 215014

Display Type : LED Status Indicators

Measuring Range : 0.2 to 10.0 m

Equipment Type : Remote Particle Counter

Port Size : 1/4 Swagelok

6501 AeroTrak-Plus Remote Particle Counter With Integrated Pump

6501 AeroTrak-Plus Remote Particle Counter With Integrated Pump

Humidity : 0 to 95% RH, noncondensing

Accuracy : Exceeds ISO 215014 and JIS B9921 standards

Display Type : Status LEDs, remote via software/web interface

Measuring Range : 0.525 m in 6 userselectable channels

Equipment Type : Remote Particle Counter with Integrated Pump

Port Size : 1/4 (6 mm) OD tube

TSI 7010-090-1V  AeroTrak-Plus Remote Active Air Sampler

TSI 7010-090-1V AeroTrak-Plus Remote Active Air Sampler

Humidity : 10% to 90% RH (noncondensing)

Accuracy : 10% (typical; sample flow rate)

Display Type : External via remote control interface

Measuring Range : 0.5 m to 25 m

Equipment Type : Remote Active Air Sampler

Port Size : 1/4 NPT

TSI 6201 AeroTrak-Plus Remote Particle Counter With Integrated Pump

TSI 6201 AeroTrak-Plus Remote Particle Counter With Integrated Pump

Humidity : 0 to 90% RH (noncondensing)

Accuracy : Complies with ISO 215014

Display Type : No display (remote monitoring via interface)

Measuring Range : 0.2 to 10 m

Equipment Type : Remote Particle Counter With Integrated Pump

Port Size : 1/4 inch tube



Back to top