6501 AeroTrak-Plus Remote Particle Counter With Integrated Pump
6501 AeroTrak-Plus Remote Particle Counter With Integrated Pump

6501 AeroTrak-Plus Remote Particle Counter With Integrated Pump

6501 AeroTrak-Plus Remote Particle Counter With Integrated Pump Specification

  • Interface Type
  • Ethernet (TCP/IP), Modbus TCP, Web Interface
  • Resolution
  • 0.1 m
  • Mounting Type
  • Panel or wall mountable
  • Port Size
  • 1/4 (6 mm) OD tube
  • Accuracy
  • Exceeds ISO 21501-4 and JIS B9921 standards
  • Display Type
  • Status LEDs, remote via software/web interface
  • Max Height
  • Approx. 110 mm
  • Power Supply
  • 24 VDC, external (10%)
  • Humidity
  • 0 to 95% RH, non-condensing
  • Temperature
  • Operating: 10 40C
  • Test Range
  • 0.5 to 25 m particle sizes
  • Equipment Type
  • Remote Particle Counter with Integrated Pump
  • Automation Grade
  • Fully Automatic
  • Measuring Range
  • 0.525 m in 6 user-selectable channels
  • Operating Voltage
  • 24 VDC
  • Features
  • Integrated pump, 6 user-configurable channels, data logging, ISO-compliant
  • Application
  • Cleanroom monitoring, controlled environment monitoring
  • Response Time
  • < 1 second
  • Usage
  • Continuous particle monitoring in critical environments
  • Capacity
  • Continuous operation
  • Machine Weight
  • Approximately 4 kg
  • Test Speed
  • 0.1 CFM (2.83 L/min)
  • Control Mode
  • Remote Control via Software/Network
  • Model
  • 6501 AeroTrak Plus
  • Enclosure Rating
  • IP 65
  • Dimensions (L x W x H)
  • 250 mm x 110 mm x 134 mm
  • Data Storage
  • Rolling buffer, up to 250,000 samples
  • Alarm Output
  • User programmable, remote notification
  • Zero Count Level
  • <1 count/5 min (per ISO 21501-4)
  • Data Output
  • Network accessible, remote download
  • Flow Rate
  • 0.1 CFM (2.83 L/min)
  • Light Source
  • Laser diode
  • Communication Protocols
  • Ethernet, Modbus TCP/IP, Browser Interface
  • Sampling Method
  • Active, internal pump-driven
 
 

About 6501 AeroTrak-Plus Remote Particle Counter With Integrated Pump

Features and Benefits

  • Easy installation and reliable operation with reduced costs
  • Reliable laser technology backed by the industrys longest warranty (five years)
  • Secure, long-term collection and storage of critical manufacturing data
  • Reduce installation costs and complexitywireless enabled with minimal infrastructure and built-in pump
  • Identifies industrys widest range of particle sizes by way of available model options
  • Simplifies integration with Ethernet or DC power
  • Reliable operation with heavy industrial electrical immunity compliance
  • Early-warning of adverse environmental trends with per second sampling
  • Predictive instrument maintenance alerts
  • ISO 14644-14 suitability for use classified
  • Sealed inlet prevents accidental ingress of cleaning solutions
  • Rapid setup and unit configuration using standard USB-C cable
  • Easy integration into TSI FMS Software with sensor auto discovery
  • Sample inlet capping auto-detect automatically stops built in pump and prevents accidental damage
  • Easy Integration into third party systems with 4-20 mA analog data output model options



Precision Particle Monitoring for Critical Environments

Equipped with an active, internal pump-driven sampling method and a high-precision laser diode, the 6501 AeroTrak-Plus ensures detection of particles from 0.5 to 25 m across six configurable channels. This facilitates accurate, continuous monitoring of air quality in cleanrooms, meeting the rigorous standards of ISO 21501-4 and JIS B9921.


Advanced Remote Access and Data Management

Utilizing Ethernet, Modbus TCP/IP, and browser interfaces, this particle counter offers seamless integration with facility monitoring systems. Data can be remotely accessed, downloaded, or managed via software, allowing for real-time oversight and rapid response. Visual status indicators and programmable alarms enhance operational confidence.


Robust Construction and Flexible Installation

With an IP65-rated enclosure, the 6501 AeroTrak-Plus withstands demanding industrial spaces. Its compact design permits easy panel or wall mounting. Reliable performance is maintained under broad humidity and temperature ranges, making it suitable for diverse cleanroom and laboratory environments.

FAQ's of 6501 AeroTrak-Plus Remote Particle Counter With Integrated Pump:


Q: How does the 6501 AeroTrak-Plus Remote Particle Counter operate?

A: The device utilizes an integrated internal pump for active sampling, drawing air at a flow rate of 0.1 CFM (2.83 L/min). It measures particle sizes from 0.5 to 25 m using a laser diode and provides data across six user-selectable channels for comprehensive air quality monitoring.

Q: What applications is this particle counter best suited for?

A: This model is ideal for continuous monitoring in cleanrooms, controlled environments, and other critical spaces where strict particulate control is required, such as pharmaceutical manufacturing, semiconductor production, and research laboratories.

Q: When should I use the programmable alarm output feature?

A: The programmable alarm output can be configured to alert users or trigger remote notifications when particle count thresholds are exceeded, enabling rapid response to potential contamination events.

Q: Where can I access the data collected by this device?

A: You can access the data remotely over a network using Ethernet (TCP/IP), Modbus TCP, or the built-in web interface. The device supports remote data downloads and provides a rolling buffer for up to 250,000 samples.

Q: What is the process for installing the AeroTrak-Plus 6501 unit?

A: The counter can be mounted on a panel or wall in your monitoring area. It requires a 24 VDC external power supply and connection to a network via Ethernet or Modbus TCP for remote operation and control.

Q: What are the benefits of choosing this model for my facility?

A: With high accuracy, ISO compliance, and automated operation, the AeroTrak-Plus 6501 enhances facility compliance, supports rapid contamination detection, and streamlines environmental monitoring through its advanced connectivity and data management features.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Online Particle Counter Category

7201 AeroTrak-Plus Remote Particle Counter

7201 AeroTrak-Plus Remote Particle Counter

Port Size : 1/4 Swagelok

Test Speed : 0.1 to 1.0 CFM (cubic feet per minute)

Accuracy : Compliant with ISO 215014

Usage : Continuous Particle Counting

Interface Type : Ethernet, Modbus TCP/IP, RS485

Mounting Type : Wall & Panel Mount

7510 AeroTrak-Plus Remote Particle Counter

7510 AeroTrak-Plus Remote Particle Counter

Port Size : 1/8 in. tubing

Test Speed : 0.1 CFM (2.83 LPM)

Accuracy : Better than 10% at 0.5 m and above

Usage : Particle counting in controlled environments

Interface Type : Ethernet (TCP/IP), Modbus TCP, BACnet IP, Ethernet/IP

Mounting Type : Wall or panel mount

TSI 7010-090-1V  AeroTrak-Plus Remote Active Air Sampler

TSI 7010-090-1V AeroTrak-Plus Remote Active Air Sampler

Port Size : 1/4 NPT

Test Speed : 90 lpm sampling rate

Accuracy : 10% (typical; sample flow rate)

Usage : Continuous remote air sampling for cleanrooms

Interface Type : Ethernet (Modbus TCP/IP), isolated RS485 (Modbus RTU)

Mounting Type : Wall or panel mountable

7310 AeroTrak-Plus Remote Particle Counter

7310 AeroTrak-Plus Remote Particle Counter

Port Size : 1/4 or 6 mm ID

Test Speed : 0.1 CFM (2.83 LPM)

Accuracy : Meets ISO 215014 and JIS B9921

Usage : Continuous particle monitoring

Interface Type : RS485, Ethernet, Modbus TCP/IP

Mounting Type : Wallmounted or panelmounted



Back to top