About V8.0 Forward Flow Fest Filter Integrity
Features
- Can test methods regarding the integrity of the filter;
- Adopt optimized Linux system;
- Optimized test operation and shortened test time;
- 10-inch true-color touch screen design, friendly human-machine interface, simple, fast and reliable operation;
- To meet offline /online testing, using pressure sensors with higher accuracy and lower deviation bands to improve the test accuracy of the instrument;
- Automatic self-test function, self-test of multiple performance functions of the instrument itself, after turning on the instrument has instrument self-test function, report faults in time.
- To implement the integrity test of an ultrafiltration system.
- Scientific user management, password login, user classification, electronic signature, etc;
- The instrument comes with an audit trail;
- Can establish 1000 sets of pre-stored programs, which meet multiple filter types and different test conditions in the field;
- Increased the display curve of diffusion flow-pressure, realized the display and printing function of three curves, optimized the air intake control unit, and greatly increased the air intake speed and stability;
- Can expand data communication and network interface requirements according to customer requirements, and support wireless communication functions;
- Test records and audit trails of the instrument both can be queried and exported;
- The built-in thermal printer avoids the risk of particle and ink contamination, and can keep the handwriting clear;
- Using Chinese and English bilingual interface;
- Multiple pressure units can be switched flexibly(mbar,kpa,psi,kgf/cm2);
- 1000 user accounts, four level of user management, and each user's authority can be determined by default or customized methods, more flexible to meet the needs of on-site production and laboratory management, and perfect user information and authority configuration;
- Can test most up to 12-core 20-inch filter cartridges, which greatly improves the user's work efficiency;
- Rich data interface, the instrument not only includes standard digital and analog interfaces (RS232 / USB);
- The independent R & D team can design specific solutions according to the needs of customers. Many years of field experience and professional services ensure that customers can use the instrument at ease, and provide technical support for the design and configuration of customer filtration systems
Advanced Integrity Testing for FiltersDesigned for laboratories and industrial settings, the V8.0 Forward Flow Fest Filter Integrity Tester delivers reliable and precise filter membrane and cartridge integrity assessments. Its automatic and manual programmable modes accommodate a variety of test requirements, while safety mechanisms and real-time data output support professional testing environments.
User-Friendly with Data ManagementFeaturing a 7-inch touch screen interface and memory to store up to 1000 test records, this tester enables hassle-free operation. Export your results easily in Excel or PDF formats for comprehensive documentation and compliance. Multilingual support ensures usability in diverse regions and teams.
Built for Accuracy and ComplianceOperating within GMP/GLP standards, the tester guarantees high accuracy (1% FS) and repeatable results. Self-calibration, programmable alarms, and robust safety features like emergency stop and over-pressure protection underline its reliability for critical testing processes.
FAQ's of V8.0 Forward Flow Fest Filter Integrity:
Q: How does the V8.0 Forward Flow Fest Filter Integrity Tester perform tests?
A: The tester uses the forward flow and bubble point methods to check the integrity of filter membranes and cartridges. It automatically manages the process, controls gas pressure, and collects data for analysis, ensuring consistent and accurate test results.
Q: What types of data outputs are available from the integrity tester?
A: Test results can be easily exported in both Excel and PDF formats. This allows users to document, share, and archive integrity test data according to their operational and compliance requirements.
Q: When should I use the self-calibration function?
A: It is advisable to use the self-calibration function before starting a new series of tests or after any maintenance procedures to ensure measurement accuracy and compliance with laboratory standards.
Q: Where is this equipment typically used?
A: The V8.0 Forward Flow Fest Filter Integrity Tester is ideal for laboratory and industrial environments-especially in settings where compliance with GMP and GLP standards is required for filter integrity assurance.
Q: What is the process for conducting a filter integrity test with this device?
A: Install the filter specimen, select the desired test parameters via the touch screen, and start the automatic or manual program. The device will control the test medium (compressed air or nitrogen), monitor pressure and flow, and alert the user at test completion or in case of errors.
Q: How does the alarm function benefit users during operation?
A: The tester's alarm system provides notifications for over-pressure, test completion, and errors, ensuring safety and minimizing the risk of procedural mistakes during the testing process.
Q: What are the advantages of the programmable control mode?
A: Programmable control allows users to customize test procedures for different filter specifications, contributing to greater versatility and more precise adherence to various testing protocols.