UV-VIS 1000 + Spectrophotomet Specification

  • Measurement Range
  • 190 - 1000 nm
  • Temperature Range
  • Room Temperature Operation
  • Voltage
  • 220 V
  • Capacity
  • 1 sample at a time
  • Model No
  • UV-VIS 1000+
  • Power Source
  • 220V AC Mains
  • Automation Grade
  • Semi-automatic
  • Feature
  • High Accuracy, Stable Performance
  • Frequency
  • 50-60 Hz
  • Accuracy
  • 0.5% T
  • Core Components
  • Light Source, Monochromator, Detector
  • Equipment Materials
  • Metal and Plastic Housing
  • Type
  • Double Beam Spectrophotometer
  • Usage
  • Laboratory, Analytical Chemistry
  • Display Type
  • Digital LCD
  • Dimension (L*W*H)
  • 420 x 280 x 180 mm
  • Weight
  • Approx. 10 kg
  • Wavelength Repeatability
  • 0.2 nm
  • Wavelength Accuracy
  • 0.5 nm
  • Photometric Range
  • -0.3 ~ 3.0 A
  • Software Compatibility
  • PC Software Included
  • Calibration
  • Automatic Wavelength Calibration
  • Stray Light
  • 0.05% T @ 220 nm, 360 nm
  • Sample Compartment
  • Standard 10mm Cuvette Holder
  • Data Output
  • USB, RS232
  • Packaging
  • Export Standard Packaging
  • Monochromator Type
  • Czerny-Turner
  • Lamp Life
  • 2000 hours (approx.)
  • Bandwidth
  • 2 nm
  • Operating Humidity
  • 85% RH (non-condensing)
  • Lamp
  • Deuterium & Tungsten
 
 

About UV-VIS 1000 + Spectrophotomet

Applications

The UV1000+ Spectrophotometer incorporates dual monochromator technology, making it well suited to even the most demanding applications in all areas of UV-Visible Spectroscopy, including:

  • Pharmaceutical
  • Material Science
  • Metrological Verification
  • Biotechnology
  • Food Safety
  • Research

Standard Features of Double Beam Double Monochromator UV 1000+:

  • Both 60mm and 150mm integrating sphere for diffuse reflectance measurements.
  • Absolute and specular reflectance measurement accessories.
  • Polarizing optics.
  • Thermostatic cell holders for temperature control.
  • Various long and short path length cell holders.
  • Automated cell changers for both sample and reference beams.
  • Tablet dissolution accessory for pharmaceutical quality control



Advanced Czerny-Turner Monochromator Technology

Harnessing the Czerny-Turner monochromator, the UV-VIS 1000+ achieves precise wavelength selection and minimal stray light interference, enhancing accuracy for all spectrophotometric measurements. This technology is essential for applications demanding high resolution and stability.


Superior Photometric Performance and Stability

With a photometric range of -0.3 to 3.0 A and accuracy up to 0.5% T, the spectrophotometer delivers reliable results for even the most delicate analyses. Its stable double beam optics reduce baseline drift and ensure repeatable, long-term measurements.


User-Friendly Operation and Versatile Connectivity

The device features a clear digital LCD for easy navigation, with automated wavelength calibration for streamlined workflows. Data can be exported via USB or RS232, while bundled PC software enhances data visualization and reporting.

FAQ's of UV-VIS 1000 + Spectrophotomet:


Q: How do I calibrate the UV-VIS 1000+ spectrophotometer?

A: The UV-VIS 1000+ is equipped with automatic wavelength calibration. Simply follow the on-screen prompts; the system uses its precision optics and built-in standard to calibrate itself, ensuring optimal accuracy for your analyses.

Q: What is the recommended process for sample measurement?

A: To measure a sample, insert a standard 10mm cuvette with your sample solution into the compartment, select your wavelength parameters using the digital display, and initiate the scan. The double beam system measures reference and sample concurrently for maximum reliability.

Q: When should I replace the light source lamps?

A: The deuterium and tungsten lamps have an approximate life span of 2000 hours. It's advisable to monitor lamp hours through the device software and replace them when they approach their expected end to maintain accurate performance.

Q: Where can I use the UV-VIS 1000+ spectrophotometer?

A: Designed for laboratory and analytical chemistry settings, the UV-VIS 1000+ is ideal for research labs, manufacturing quality control, and academic institutions across India. Its durable packaging and robust materials support demanding operational environments.

Q: What are the benefits of using a double beam spectrophotometer like the UV-VIS 1000+?

A: Double beam technology allows simultaneous reference and sample measurement, enhancing stability and reducing baseline drift. This results in higher accuracy and reproducibility, especially important for quantitative analyses.

Q: How compatible is the instrument with data management systems?

A: The UV-VIS 1000+ offers USB and RS232 ports for seamless data transfer, and comes with PC software for advanced data analysis, graphical reporting, and archival, ensuring integration with modern lab information systems.

Q: What is the humidity range for operating this spectrophotometer?

A: The instrument operates effectively in environments with humidity levels up to 85% RH (non-condensing), making it suitable for most standard laboratory conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Spectrophotometer Category

UV 3200 Spectrophotometer

UV 3200 Spectrophotometer

Measurement Range : 190 1100 nm

Equipment Materials : Corrosionresistant metal and highdurability plastic housing

Temperature Range : Ambient, not temperature controlled Fahrenheit (oF)

Voltage : 220V AC / 110V AC Volt (v)

Dimension (L*W*H) : 200x600x450 Nanometer (nm)

Type : Double Beam UVVisible Spectrophotometer

Dual Beam UV-VIS 2000 Spectrophotometer

Dual Beam UV-VIS 2000 Spectrophotometer

Measurement Range : 190 nm to 1100 nm

Equipment Materials : Highgrade metal and ABS body

Temperature Range : 5C to 45C

Voltage : 220 V

Dimension (L*W*H) : 625 x 430 x 210 mm

Type : Dual Beam UVVIS Spectrophotometer

Dual Beam UV-VIS 2002 XE Spectrophotometer

Dual Beam UV-VIS 2002 XE Spectrophotometer

Measurement Range : 190 1100 nm

Equipment Materials : Aluminum housing, powdercoated; quartz optics; ABS body

Temperature Range : Room Temperature to 50C (with optional cell holder)

Voltage : 220 V

Dimension (L*W*H) : 600 x 450 x 210 mm

Type : Dual Beam UVVIS Spectrophotometer

UV-990 Spectrophotometer

UV-990 Spectrophotometer

Measurement Range : 190 nm 1100 nm

Equipment Materials : Highgrade Optical Components, Robust Casing

Temperature Range : Room Temperature Operation

Voltage : 220 V

Dimension (L*W*H) : 530 x 400 x 220 mm

Type : UVVisible Spectrophotometer



Back to top