Potentiometric Auto Titrator Titra Smart
Potentiometric Auto Titrator Titra Smart

Potentiometric Auto Titrator Titra Smart

Potentiometric Auto Titrator Titra Smart Specification

  • Power Source
  • 230V AC mains
  • Core Components
  • Magnetic stirrer, burette, piston, electrode, control panel
  • Voltage
  • 230 V AC
  • Capacity
  • 10 ml, 25 ml burette options
  • Accuracy
  • 0.1% of full scale
  • Temperature Range
  • 10C to 45C
  • Model No
  • Titra Smart
  • Frequency
  • 50 Hz
  • Measurement Range
  • 0.01 ml - 999.9 ml
  • Automation Grade
  • Automatic
  • Feature
  • Auto titration, endpoint detection, programmable
  • Equipment Materials
  • Corrosion-resistant ABS body, glass burette, PTFE parts
  • Type
  • Potentiometric Auto Titrator
  • Usage
  • Laboratory analysis, chemical titrations
  • Display Type
  • Large LCD display
  • Dimension (L*W*H)
  • 250 mm 350 mm 200 mm
  • Weight
  • Approx. 4-5 kg
  • Calibration
  • Single and multi-point calibration
  • Ambient Operating Humidity
  • Up to 85% RH non-condensing
  • Burette Resolution
  • 0.01 ml
  • Electrode Type
  • Combined pH electrode or specific ion electrode
  • Number of Methods Programmable
  • Up to 20 methods
  • Stirring System
  • Magnetic stirrer with adjustable speed
  • Titration Types Supported
  • Acid-base, Redox, Non-aqueous, Complexometric, Precipitation
  • Result Output
  • Direct print via printer port
  • Connectivity
  • RS232/USB interface for data transfer
  • Data Storage
  • Internal memory for up to 100 results
  • Sample Volume
  • 1 ml 200 ml
 
 

About Potentiometric Auto Titrator Titra Smart

Standard Features of Potentiometric Auto Titrator Titra Smart

  • User Interactive Design: Easy to operate with protection against invalid entries.
  • Vortex Stirrer: For vigorous and homogeneous stirring, with a specially designed glass propeller for total chemical inertness.
  • Quick Interchangeable Burette Assemblies: Imported burette assemblies with intelligent recognition for volume size. Burette factor for dispensing corrections is available for accurate endpoint calculations.
  • Peripheral Connectivity Recognition: The system detects proper connectivity of peripherals (burette, stirrer, electrode) and provides an indication in case of improper connectivity.
  • Composite Differential Electrode Amplifier Unit: Used for Potentiometric and KF titrations, providing connectivity to various electrodes. The temperature sensor with a 4-line measurement technique ensures correct temperature indication.
  • Large Memory Capacity: For storing methods with scientific parameters, ensuring GLP compliance.
  • Standardized Titration Modes: Includes incremental and equilibrium titration methods.
  • Automatic Electrode Type Selection: By selecting a titration method, the instrument automatically identifies the appropriate electrode for use.
  • Titration Data Display: During titration, the measured variable (electrode potential or pH value) is shown, along with dispensed volume and the number of detected end points (EP).
  • User-Selectable End Point (EP) Evaluation: Up to 9 EPs during the run, with calculations by first, last, largest, all, or selected EP. Results and printouts are displayed.
  • Sample and Titrant Identification: The system records sample name, titrant name, identification number, date, and electrode type used for authentication. Additionally, daily auto-incremented run numbers, factory-entered customer name, and instrument serial number ensure GLP compliance.
  • Manual Titration Capability: Can be used as a dispenser for fixed volume dosing or dilution, with user-defined dose and mV indication.
  • Predispense Facility: Selectable dose and time for quick titrant addition without disturbing the titration trend.
  • Automatic Molarity Evaluation: For titrant standardization.
  • ASTM Compliance: Compliant with ASTM D664, D2896 & D4739 for TAN and TBN analysis for oil samples.
  • Titrant Temperature Factor: For volume correction.
  • Result Recalculation: Facilities for obtaining printouts in different units such as molarity, factor, % assay (wt), % volume (ml), ppm, mg/l, mg/g, ml/g, g/l, meq/l, mol/kg, TAN & TBN for oil samples.
  • User-Defined Formula: Allows the use of constant codes (FC 1, FC 2, FC 3, FC 4) for custom calculations.
  • Reprocessing of Threshold and EP: Recalculation of EP without the need for a new run.
  • Statistic Function: For analyzing Mean, Standard Deviation (S.D.), Relative Standard Deviation (R.S.D.), and Coefficient of Variation (C.V.) of the last 10 repeat runs, with results available for viewing or printing.

User-Programmed Selectivity for Report Format (GLP Compliant):

A) Report with titration parameters and results.

B) Data table with mV, pH, mV, mV/ml, 2nd derivative & volume (l).

C) Graphics report showing mV vs l titration curve.

D) Graphics report of the 1st derivative graph vs l titration curve.

E) Graphical report of the 2nd derivative curve.

F) Report of method parameters.

G) Condensed report of titration parameters and results.

H) Auto evaluation report for multi EP samples (e.g., EP1, EP2-EP).

  • Reports Accessibility: Reports can be obtained even after resetting, power off, or power failure conditions.
  • Time Display: With run time indication for report printout.
  • Balance Interface: To directly transfer the sample weight.
  • Titration Mode Conversion: TITRA can be converted to perform Karl Fischer titrations by changing the burette assembly. All specifications of LABINDIA Karl Fischer Titrator are applicable.
  • Online Graphic Display: To analyze the sample reaction trend.
  • Syringe Filled Status Display: On the screen for better monitoring.

21 CFR PART 11 COMPLIANCE

  • Audit Trail: For all activities, with search facilities, report generation, and printing.
  • 200 User IDs: Alphanumeric entries for user name, password, and role-based privilege selection.
  • Multi-Level Roles: With password protection and complexity.
  • User Authentication: Performed for every operation done by the user.
  • Customizable PDF Reports: Reports can be printed in a customizable PDF format.
  • USB Printing: Eliminates the need for a serial port. Users can take printouts on any local or network printer.
  • Electronic Signature Functionality: For security and compliance.
  • Manual Archive & Data Backup Facility: Available to ensure data integrity



Flexible Titration Solutions

Titra Smart accommodates diverse laboratory needs by supporting multiple titration types-acid-base, redox, non-aqueous, complexometric, and precipitation-making it suitable for a wide range of chemical analyses. Its versatility meets the rigorous standards of research labs, quality control facilities, and educational institutions alike.


Precision and Efficiency

This automated titrator ensures high precision with a burette resolution of 0.01 ml and accurate titrant delivery, while a magnetic stirrer with adjustable speed provides optimal mixing. Programmable up to 20 methods, Titra Smart streamlines repetitive workflows, ensuring reliable and reproducible results from 1 ml to 200 ml sample volumes.


User-Focused Design and Data Management

Featuring a large LCD display, intuitive interface, and durable ABS, glass, and PTFE construction, Titra Smart is built for user convenience and longevity. Internal memory stores up to 100 results, and seamless connectivity via RS232/USB allows for efficient data transfer and documentation, ensuring full compliance and traceability in laboratory environments.

FAQ's of Potentiometric Auto Titrator Titra Smart:


Q: How does the Titra Smart Auto Titrator perform endpoint detection during titrations?

A: The Titra Smart utilizes potentiometric measurement with either a combined pH electrode or a specific ion electrode, depending on your application. The device continuously monitors the electrode's potential and accurately detects the titration endpoint automatically, ensuring consistent and reliable results for various methods.

Q: What types of chemical titrations can be conducted with this titrator?

A: This instrument supports acid-base, redox, non-aqueous, complexometric, and precipitation titrations. Its versatility makes it suitable for a broad spectrum of analyses, covering different industries and research fields, all programmable within up to 20 custom titration methods.

Q: When should I calibrate the electrodes and how is calibration performed?

A: Calibration should be performed at installation, before first use, and periodically as recommended in your laboratory protocol or after cleaning/changing the electrode. The Titra Smart offers both single and multi-point calibration options via its user-friendly interface, ensuring measurement accuracy and reproducibility.

Q: Where can I transfer or store titration data collected from the Titra Smart?

A: Titra Smart provides multiple options: data can be stored internally for up to 100 results, transferred to external systems via RS232/USB, or printed directly through the printer port. This flexibility allows for efficient record-keeping and result documentation.

Q: What is the process for programming a titration method on the Titra Smart?

A: Programming is straightforward: use the large LCD display and control panel to select a new method, specify titration parameters such as type, detection mode, burette size, stirring speed, and endpoint criteria. Up to 20 methods can be saved for quick retrieval and repeatability.

Q: How does the magnetic stirring system enhance titration accuracy?

A: The built-in magnetic stirrer, featuring adjustable speed, ensures homogenous mixing of the sample and titrant. This even distribution is crucial for reaction completeness and contributes significantly to the titration's precision, regardless of sample volume or titration type.

Q: What are the main benefits of using Titra Smart for laboratory analysis?

A: Key benefits include high-accuracy automated titration, versatility for multiple applications, ease of programming and data management, robust corrosion-resistant construction, and user-friendly operation. These features collectively enhance laboratory productivity and compliance in both routine and specialized analyses.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Automatic Titrators Category

Automatic Karl Fischer Titrator KAFI + SMART

Automatic Karl Fischer Titrator KAFI + SMART

Voltage : 230V AC

Core Components : Titration Cell, Dosing Pump, Electrode, Stirrer

Power Source : Electric

Equipment Materials : ABS Body, Glass, SS316 Electrodes

Capacity : 2200 mg H2O

Dimension (L*W*H) : 330 x 310 x 160 mm

Karl Fischer Titrator KAFI+

Karl Fischer Titrator KAFI+

Voltage : 230V AC

Core Components : Electrolytic cell, titration vessel, electrodes, magnetic stirrer

Power Source : AC power

Equipment Materials : Corrosion resistant plastic and stainless steel

Capacity : 10 g H2O to 200 mg H2O

Dimension (L*W*H) : 305 x 310 x 145 mm

Potentiometric Auto Titrator Titra+

Potentiometric Auto Titrator Titra+

Voltage : 230V AC

Core Components : Burette, magnetic stirrer, electrodes, control unit

Power Source : AC mains

Equipment Materials : Corrosion resistant, chemicalproof plastic body

Capacity : 10 ml and 20 ml burette options

Dimension (L*W*H) : 400 x 320 x 140 mm



Back to top