Karl Fischer Titrator KAFI+ Specification

  • Temperature Range
  • Ambient
  • Accuracy
  • 0.3% (for 10 mg to 200 mg H2O)
  • Automation Grade
  • Semi-automatic
  • Voltage
  • 230V AC
  • Frequency
  • 50 Hz
  • Power Source
  • AC power
  • Capacity
  • 10 g H2O to 200 mg H2O
  • Core Components
  • Electrolytic cell, titration vessel, electrodes, magnetic stirrer
  • Measurement Range
  • Up to 200 mg H2O
  • Model No
  • KAFI+
  • Feature
  • Auto endpoint determination, high sensitivity, low drift
  • Equipment Materials
  • Corrosion resistant plastic and stainless steel
  • Type
  • Coulometric Karl Fischer Titrator
  • Usage
  • Laboratory moisture determination
  • Display Type
  • Digital (LCD) Display
  • Dimension (L*W*H)
  • 305 x 310 x 145 mm
  • Weight
  • 6.5 kg (approx.)
  • Stirrer
  • Magnetic, variable speed
  • Titration Method
  • Coulometric
  • Electrode Material
  • Platinum
  • Glassware Volume
  • 100 ml
  • Sample Introduction
  • Manual/Syringe
  • Resolution
  • 0.1 g H2O
  • Languages Supported
  • English
  • Interface
  • RS232 for printer/PC connection
  • Current Output
  • Maximum 400 mA
  • Approval/Compliance
  • CE Marked
  • Ambient Humidity Tolerance
  • Up to 80% RH
  • Data Storage
  • Internal memory for titration results
 
 

About Karl Fischer Titrator KAFI+

Standard Features of Automatic Karl Fischer Titrator (Kafi +)

  • Advanced Microcontroller-Based Design: User-friendly, state-of-the-art product design with alphanumeric splash waterproof polyester soft keys for the keyboard. User-interactive software in dialogue mode for ease of operation, with protection against invalid entries.
  • Quick Interchangeable Burette Assemblies: Imported burette assemblies with intelligent recognition for volume size. Burette validation factor for dispensing correction is available for true endpoint volume.
  • Alphanumeric Entry: Allows entry of sample name & identification number with date and time for authentication. Daily auto-incremented run number and factory-entered customer name & instrument serial number on report printouts ensure the system is foolproof and GLP compliant.
  • Moisture Leak Monitoring: Quick monitoring and automatic neutralization of moisture leakage into the vessel to keep it ready for the next titration.
  • End Point Delay: Up to 100 seconds for slow moisture-releasing samples.
  • Titration Run Start: The titration run can be started with the parameters of the last run.
  • Leak Rate Correction: On-line leak rate correction available.
  • Magnetic Stirrer: Microcontroller-based variable speed magnetic stirrer with digital indication.

Calculation Modes:

  • Weight/Weight
  • Volume/Volume
  • Volume/Density

Selectable Report Format (GLP Compliant):

  • Report with titration parameters and results.
  • Report of method parameters.
  • Condensed report of titration parameters and results.
  • Statistics report for the last 10 repeat run analyses.
  • Report Accessibility: Reports can be obtained even after resetting, power off, or power failure.
  • Statistic Function: Run selectivity to find the mean, standard deviation (S.D.), relative standard deviation (R.S.D.), and coefficient of variation (C.V.) of the last 10 repeat run results, which can be viewed or printed.
  • Storage of Results: Storage of the last ten results with reprocessing facilities.
  • ASTM Standard Compliance: Compliant for the analysis of oil samples.
  • Real-Time Clock (RTC): For date & time display and report printout with run time indication.
  • Balance Interface: Direct transfer of sample weight.
  • Two-Tier Password Protection: Admin and user-level password protection for method editing.

Optional Features:

  • IQ, OQ, PQ documents available.
  • Data downloading facility to PC via 21CFR compliant EDC21 software



Precision Moisture Analysis Simplified

The KAFI+ ensures accurate and reliable moisture determination in laboratory settings. Its digital LCD interface, auto endpoint detection, and low drift operation guarantee dependable results every time. With a wide measurement range and high sensitivity, it caters to diverse analytical requirements while maintaining user-friendly operation.


Robust Design and Versatile Functionality

Constructed from corrosion-resistant plastic and stainless steel, the KAFI+ is built to withstand rigorous laboratory use. Featuring a magnetic stirrer with variable speed, platinum electrodes for optimal conductivity, and a 100 ml glassware volume, it suits a broad range of sample types and volumes.


Seamless Data Management and Connectivity

Equipped with internal memory for titration data and an RS232 interface, the KAFI+ streamlines data transfer and archiving. Results are easily accessible and exportable, enabling integration with printers or computers for comprehensive laboratory documentation and workflow efficiency.

FAQ's of Karl Fischer Titrator KAFI+:


Q: How does the Karl Fischer Titrator KAFI+ determine moisture content?

A: The KAFI+ utilizes the coulometric titration method, which measures the amount of electrical charge required to react with water in the sample. This allows for precise determination of water content from 10 g to 200 mg H2O.

Q: What are the main benefits of using the KAFI+ in a laboratory setting?

A: The KAFI+ offers high sensitivity (0.1 g H2O resolution), automatic endpoint determination, and low drift for reliable results. Its digital LCD display, internal memory for result storage, and rapid analysis improve efficiency and data management.

Q: When should I opt for the KAFI+ over other moisture analyzers?

A: Choose the KAFI+ when you require precise moisture determination in small to moderate sample sizes, need compliance with CE standards, or require automated and accurate results in environments with up to 80% ambient humidity.

Q: Where can the KAFI+ be reliably used?

A: This titrator is ideal for laboratories, research institutes, and quality control departments. Its robust design and materials make it suitable for demanding laboratory environments across India.

Q: What is the process for introducing samples and starting a titration with the KAFI+?

A: Samples are manually introduced using a syringe into the titration vessel. The magnetic stirrer ensures homogeneous mixing, and the device automatically tracks the titration, determining the endpoint and storing results for review.

Q: How does the KAFI+ ensure accuracy and minimize errors during titration?

A: With platinum electrodes, precise current control (up to 400 mA), and automatic endpoint detection, the KAFI+ minimizes operator error and drift, ensuring consistent accuracy within 0.3% over its specified range.

Q: What are the key advantages regarding the KAFI+'s connectivity and data storage?

A: The KAFI+ features RS232 connectivity for seamless integration with PCs and printers. Its internal memory securely stores titration results, facilitating traceability and efficient data management within laboratory workflows.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Automatic Titrators Category

Automatic Karl Fischer Titrator KAFI + SMART

Automatic Karl Fischer Titrator KAFI + SMART

Core Components : Titration Cell, Dosing Pump, Electrode, Stirrer

Capacity : 2200 mg H2O

Equipment Materials : ABS Body, Glass, SS316 Electrodes

Power Source : Electric

Frequency : 50 Hz

Voltage : 230V AC

Potentiometric Auto Titrator Titra+

Potentiometric Auto Titrator Titra+

Core Components : Burette, magnetic stirrer, electrodes, control unit

Capacity : 10 ml and 20 ml burette options

Equipment Materials : Corrosion resistant, chemicalproof plastic body

Power Source : AC mains

Frequency : 50/60 Hz

Voltage : 230V AC

Potentiometric Auto Titrator Titra Smart

Potentiometric Auto Titrator Titra Smart

Core Components : Magnetic stirrer, burette, piston, electrode, control panel

Capacity : 10 ml, 25 ml burette options

Equipment Materials : Corrosionresistant ABS body, glass burette, PTFE parts

Power Source : 230V AC mains

Frequency : 50 Hz

Voltage : 230 V AC



Back to top