PICO pH - Conductivity Meter - Salinity
PICO pH - Conductivity Meter - Salinity

PICO pH - Conductivity Meter - Salinity

PICO pH - Conductivity Meter - Salinity Specification

  • Operating Voltage
  • 6V (4 x 1.5V AA batteries)
  • Test Range
  • pH: 0.00 to 14.00; Conductivity: 0 S/cm to 19.99 mS/cm; Salinity: 0.00 to 70.00 ppt
  • Measuring Range
  • pH: 0.00-14.00; Conductivity: 0-19.99 mS/cm; Salinity: 0.00-70.00 ppt
  • Accuracy
  • pH: 0.01 pH; Conductivity: 1% F.S.; Salinity: 1% F.S.
  • Number of Specimens
  • Single-point measurement
  • Resolution
  • pH: 0.01 pH; Conductivity: 0.01 S/cm; Salinity: 0.01 ppt
  • Display Type
  • Large backlit LCD
  • Response Time
  • <30 sec
  • Humidity
  • 85% RH (non-condensing)
  • Application
  • Water quality analysis, lab and field use
  • Mounting Type
  • Portable / Table-top
  • Automation Grade
  • Semi-automatic (auto/manual calibration)
  • Interface Type
  • No data interface (basic unit)
  • Power Supply
  • 4 x 1.5V AA alkaline batteries
  • Equipment Type
  • Tabletop / Portable Meter
  • Features
  • Auto/manual temperature compensation, auto calibration, hold function, waterproof housing
  • Port Size
  • Standard BNC for pH electrode, 6-pin DIN for conductivity sensor
  • Temperature
  • 0C to 60C
  • Usage
  • pH, conductivity and salinity measurement
  • Machine Weight
  • 600 g (including batteries)
  • Control Mode
  • Manual & Auto calibration
  • Operating Environment
  • Field and laboratory conditions
  • Calibration
  • Auto/manual, up to 3-point for pH, 1-point for conductivity
  • Battery Life
  • >500 hours in continuous operation
  • Waterproof Rating
  • IP54
  • Salinity Compensation
  • Automatic
  • Temperature Compensation
  • Automatic: 0C60C
  • pH Electrode
  • Standard BNC; included in the kit
 
 

About PICO pH - Conductivity Meter - Salinity

Standard Features of PICO pH/Conductivity Meter/Salinity:

  • Advanced microcontroller-based, user-friendly, state-of-the-art design
  • PICO pH Meter complies with USP and DIN standards
  • Sleek moulded cabinet with alphanumeric splash-proof polyester keyboard with soft keys
  • User-interactive software in dialogue mode for ease of operation with protection against invalid entries
  • 20 x 2 line backlit LCD display
  • Simultaneous measurement of pH, mV, and temperature. Conductivity, TDS & Salinity optional

Non-volatile memory storage of:

  • 40 pH and 40 mV readings with temperature in pre-selected GLP or Non-GLP format
  • 24 data memory readings of pH, temperature, and time in data logging mode (optional)

  • Password protection for calibration data and stored readings
  • Calibration data with date and time stamp for authentication. Facility to view the calibration data
  • Calibration reminder alarm
  • Alphanumeric entries of sample name, identification number for authentication
  • Input stability indicator for reproducible results
  • Built-in real-time clock (RTC) for time display and on report printout
  • Factory-entered CUSTOMER NAME on report printout for authentication
  • Error indication helps the user to trace the problem
  • Audible beep indication during valid key operation
  • PC compatibility for data downloading (optional)
  • Combined pH and conductivity instrument is available

pH Meter:

  • Automatic temperature compensation by Pt.100 temperature sensor. Range 0 to 150C
  • 3-point (Isopotential) or 5-point (linear or segmented) calibration protocol

Conductivity Meter:

  • Automatic evaluation of CELL constant with standard solution
  • User-selectable temperature coefficient for automatic temperature compensation, through special TEMPCO key
  • Input stability indicator for reproducible results



Designed for Versatile Water Analysis

Ideal for both laboratory and field operations, the PICO pH-Conductivity Meter is engineered to provide reliable measurements for pH, conductivity, and salinity. The device's waterproof, portable design combined with intuitive controls ensures accurate water quality testing, whether you are at a remote site or in a controlled lab setting.


Advanced Calibration & Compensation

Benefit from automatic and manual calibration options, allowing for up to three-point calibration for pH and single-point calibration for conductivity. Automatic temperature and salinity compensation enhance accuracy under various environmental conditions, ensuring trustworthy readings every time.


Ease of Use & Durability

Operated via simple interface options and featuring a large, backlit LCD for clear readings, the meter is built to withstand demanding workplace environments. Its IP54 rating protects against dust and splashes, while long battery life supports continuous operational needs for water quality professionals.

FAQ's of PICO pH - Conductivity Meter - Salinity:


Q: How do I calibrate the PICO pH-Conductivity Meter and what calibration options are available?

A: The meter supports both automatic and manual calibration. For pH, up to three-point calibration can be performed, ensuring precise measurements. Conductivity calibration is available at a single point. To calibrate, follow the on-screen prompts or refer to the user manual for step-by-step guidance.

Q: What types of water samples can I measure with this device and where is it suitable for use?

A: The PICO meter is designed for broad application, from laboratory water analysis to field sampling of freshwater and seawater. Its robust, portable construction and automatic compensation features enable reliable testing in varied environmental conditions and locations.

Q: When should I replace the pH electrode or conductivity sensor, and what connectors are supported?

A: Replace the pH electrode if you notice unstable or inaccurate readings after calibration, or after extended use as recommended by the manufacturer. The meter uses a standard BNC port for the pH electrode and a 6-pin DIN for the conductivity sensor, allowing straightforward replacements.

Q: What is the process for measuring pH, conductivity, and salinity?

A: Insert the appropriate electrode or sensor as indicated, power on the device, and immerse it in the sample solution. The device will automatically compensate for temperature and salinity. Readings are displayed on the large backlit LCD, usually within 30 seconds.

Q: How does automatic compensation enhance measurement accuracy?

A: Automatic temperature (0C-60C) and salinity compensation adjust readings to eliminate effects from environmental fluctuations, resulting in more precise pH, conductivity, and salinity measurements across various sample conditions.

Q: What are the key benefits of using the PICO pH-Conductivity Meter for water quality analysis?

A: The meter offers a combination of accuracy, convenience, and portability. Features such as waterproofing, long battery life, quick calibration, and robust compensation make it a reliable tool for continuous professional water testing in field and laboratory environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PH Meters-Conductivity Meter Category

Phan pH Meter

Phan pH Meter

Accuracy : 0.1 pH

Resolution : 0.01 pH

Mounting Type : Handheld

Operating Voltage : 4.5V

Automation Grade : Manual

Measuring Range : 0.00 to 14.00 pH

Pico Ph Meter

Pico Ph Meter

Accuracy : 0.1 pH

Resolution : 0.01 pH

Mounting Type : Handheld

Operating Voltage : 9V Battery

Automation Grade : Manual

Measuring Range : 0.00 to 14.00 pH



Back to top