AirAssure 8144-2 Indoor Air Quality Monitor
AirAssure 8144-2 Indoor Air Quality Monitor

AirAssure 8144-2 Indoor Air Quality Monitor

AirAssure 8144-2 Indoor Air Quality Monitor Specification

  • Resistance
  • Not applicable (solid-state electronics)
  • Output
  • Wi-Fi, Ethernet, Cloud, and Relay outputs
  • Theory
  • Laser particle counter and multi-gas sensing technologies
  • Type
  • Indoor Air Quality Monitor
  • Accuracy
  • 10% for particulate measurement, 2% for gas sensors
  • Operating Voltage
  • 24 V DC (100-240 V AC adapter available)
  • Output Voltage
  • 24 V DC nominal
  • Compensated Temperature
  • Automatic compensation within operating range
  • Storage Temperature
  • -10C to 60C
  • Operating Temperature
  • 0C to 45C
  • Dimensions
  • 196 mm x 230 mm x 53 mm
  • Housing Material
  • ABS plastic, flame retardant
  • Mounting
  • Wall-mount or desktop
  • Sensor Technology
  • Laser scattering, NDIR, MOS, and electrochemical sensors
  • Ingress Protection
  • IP20
  • Data Logging
  • Onboard storage and cloud integration
  • Measured Parameters
  • PM1, PM2.5, PM4, PM10, CO2, TVOC, Temperature, Relative Humidity, Barometric Pressure
  • Display
  • Integrated color touchscreen
 
 

About AirAssure 8144-2 Indoor Air Quality Monitor

Features and Benefits

  • Measure aerosol concentrations corresponding to PM1, PM2.5, respirable, or PM10 size fractions
  • Lightweight and portable
  • Manual and programmable data logging functions
  • Single point data logging capability
  • Handheld unit
  • Aerosol concentration range 0.001 to 150 mg/m 3

Applications

  • Industrial/occupational hygiene surveys
  • Indoor air quality investigations
  • Point source location monitoring
  • Baseline trending and screening
  • Engineering control evaluations

Included Items

  • Carrying case
  • Rechargeable 3600 mAH Li-Ion battery
  • Switching power supply with universal line cords
  • TrakPro data analysis software
  • Zero filter
  • USB (device and host) computer cable
  • Inlet cap (x2)
  • 10-mm nylon Dorr-Oliver Cyclone
  • Impactor kit (with PM1, PM2.5, PM4, PM10 impactors, impactor plates (x2), and impactor oil)
  • Sample extension tube (3-ft/1-m)
  • Sheath air HEPA filters (x8)
  • Filter removal tool
  • Screwdriver
  • Operation service manual
  • Calibration certificate
  • 2-year warranty



Comprehensive Air Quality Monitoring

Monitor vital air quality parameters, including various particulate sizes, CO2, and TVOC, alongside environmental factors like temperature and humidity. Advanced multi-sensor technology ensures precise readouts, making the AirAssure 8144-2 essential for maintaining healthy indoor air.


User-Friendly Operation and Display

With its integrated color touchscreen, the device offers intuitive navigation and easy reading of real-time data. Its design supports both wall-mount and desktop setups, adapting effortlessly to different workspace environments.


Reliable Storage and Connectivity

Make use of onboard data storage and seamless cloud integration for remote monitoring and record-keeping. Wi-Fi, Ethernet, and relay outputs support varied network and control needs for commercial and institutional applications in India.

FAQ's of AirAssure 8144-2 Indoor Air Quality Monitor:


Q: How does the AirAssure 8144-2 measure indoor air quality?

A: The AirAssure 8144-2 leverages laser scattering for particulate detection and NDIR, MOS, and electrochemical sensors for gases like CO2 and TVOC. It samples air continuously, delivering precise, real-time data on an integrated color touchscreen.

Q: What parameters can I monitor with the AirAssure 8144-2?

A: You can monitor PM1, PM2.5, PM4, PM10, CO2, TVOC, temperature, relative humidity, and barometric pressure. The monitor offers 10% accuracy for particulates and 2% for gas measurements.

Q: Where can the AirAssure 8144-2 be installed?

A: This monitor can be conveniently wall-mounted or placed on a desktop, allowing flexibility in positioning for offices, schools, hospitals, or other indoor environments across India.

Q: When should I use the AirAssure 8144-2?

A: Use this device for continuous indoor air quality assessment, especially in environments requiring compliant or healthy air standards. Its real-time alerts and data logging help identify pollution trends or HVAC performance issues.

Q: What data storage and output options are available?

A: The AirAssure 8144-2 supports onboard storage and cloud integration, allowing for comprehensive historical analysis. Data can be accessed through Wi-Fi, Ethernet, cloud services, or relay outputs for automation and building management systems.

Q: How does the device ensure measurement accuracy?

A: The monitor features automatic temperature compensation and advanced sensor technology to maintain reliability within the operating range (0C to 45C), providing dependable results over time.

Q: What are the primary benefits of using the AirAssure 8144-2 in my facility?

A: This device provides actionable air quality data, supports compliance, improves occupant well-being, and helps optimize ventilation strategies with its robust measurement range and flexible connectivity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Monitor Category

7575 Q-Trak Indoor Air Quality Monitor

7575 Q-Trak Indoor Air Quality Monitor

Type : Trak Indoor Air Quality Monitor

7545 IAQ-Calc Indoor Air Quality Meters

7545 IAQ-Calc Indoor Air Quality Meters

Type : Portable IAQ Meter

Theory : Other, NDIR (NonDispersive Infrared) technology for CO2 measurement

Operating Temperature : 0 to 50 C

Output Voltage : 5 VDC

Operating Voltage : 9 V alkaline battery

Output : Other, Digital display, RS232 interface

7515 IAQ-Calc Indoor Air Quality Meters

7515 IAQ-Calc Indoor Air Quality Meters

Type : Handheld Indoor Air Quality Meter

Theory : Other, NonDispersive Infrared (NDIR) for CO2, Electrochemical for temperature and humidity

Operating Temperature : 0 to 50C (32 to 122F)

Output Voltage : Not Applicable (digital output)

Operating Voltage : 4 x AA Alkaline Batteries or AC adapter

Output : Other, Digital LCD Display, RS232 interface

7525 IAQ-Calc Indoor Air Quality Meters

7525 IAQ-Calc Indoor Air Quality Meters

Type : Portable Indoor Air Quality Meter

Theory : Other, NDIR (Nondispersive infrared) for CO, Thermistor for temperature, Capacitive sensor for humidity

Operating Temperature : 0 to 50C

Output Voltage : Not directly applicable (digital output)

Operating Voltage : 4 AA alkaline batteries or AC adapter

Output : Other, Digital display and RS232 serial interface



Back to top