8715 DP-Calc Micromanometer Specification

  • Humidity %
  • 0 to 95% RH non-condensing
  • Application Media
  • Air
  • Pressure Range
  • -3,735 Pa to +3,735 Pa
  • Resolution
  • 0.1 Pa
  • Measurement Range
  • -3,735 to +3,735 Pa
  • Connectivity Type
  • RS-232 serial interface
  • Flow Rate
  • With optional probe
  • Sensor Type
  • Differential Pressure Sensor
  • Equipment Type
  • Micromanometer
  • Protection
  • Compact, robust case
  • Temperature Range
  • 0C to 50C (32F to 122F)
  • Material
  • High-impact plastic housing
  • Power Supply
  • 4 x AA alkaline batteries or optional AC adapter
  • Power Consumption
  • Low power consumption (battery life up to 100 hours)
  • Accuracy
  • 1% of reading 1 Pa
  • Display Type
  • Digital LCD display
  • Range
  • 3,735 Pa (15 in. H2O)
  • Backlight
  • Yes, for low light operation
  • Mounting
  • Handheld or tripod mountable
  • Dimensions
  • 84 x 190 x 44 mm (3.3 x 7.5 x 1.7 in.)
  • Operating Altitude
  • Up to 2,000 m
  • Alarms
  • Audible and visual (configurable)
  • Weight
  • 250 g (8.8 oz) including batteries
  • Overpressure Protection
  • 10 kPa maximum
  • Zero Adjustment
  • Auto-zeroing
  • Compliance
  • CE Marked
  • Data Logging
  • Up to 12,700 samples (with optional logging upgrade)
  • Units Supported
  • Pa, in. H2O, mm H2O, mbar, psi
 
 

About 8715 DP-Calc Micromanometer

Applications

  • Energy efficiency studies
  • Fume hood and biological safety cabinet face velocity spot checking
  • HVAC system testing, adjusting and balancing
  • Building and system commissioning
  • Cleanroom testing

Included Items

  • Manometer with carrying case
  • (4) AA size rechargeable NiMH batteries
  • Multi-country AC adapter
  • 18 in. (46 cm) Pitot probe
  • (2) Static Pressure probes
  • 16 ft (4.8 m) Neoprene tubing
  • Downloading software
  • USB interface cable
  • NIST-traceable calibration certificate
  • Manual
  • Image shown features standard and optional accessories.

Features and benefits

  • Accurately measures pressure, velocity and flow to help you meet industry standards
  • Auto-zeroing pressure sensor reduces user-steps and saves time
  • Automatic density correction increases reading accuracy
  • Intuitive menu structure allows for ease of use and setup
  • Integrated Log-Tchebycheff duct traverse application simplifies calculations
  • Bluetooth communications for transferring data or remote polling
  • Includes downloading software with USB cable
  • Accommodates optional pitot, air flow (straight pitot), temperature/relative humidity, velocity matrix, or thermoanemometer probes for use in multiple applications
  • Large graphic display with backlight offers easy-to-use interface
  • Displays up to five measurements simultaneously
  • On-screen messages and instructions
  • Programmed for multiple languages



Precise Differential Pressure Measurement

Engineered for reliability, the 8715 DP-Calc Micromanometer delivers precise differential pressure readings across a wide range. Perfect for professionals in HVAC, environmental monitoring, and industrial applications, its high accuracy and fine resolution ensure dependable results even in variable settings.


User-Friendly Operation and Durability

This micromanometer is designed for convenience and longevity, featuring a compact, lightweight design, robust high-impact plastic housing, and low power consumption. The intuitive interface, automatic zero adjustment, configurable alarms, and clear LCD backlighting make it easy to operate in diverse environments.


Flexible Data Logging and Connectivity

Equipped with an RS-232 interface and optional data logging capabilities for up to 12,700 samples, the 8715 DP-Calc supports thorough data management and transfer. Users can choose handheld use or tripod mounting, while audible and visual alarms increase operational flexibility and safety.

FAQ's of 8715 DP-Calc Micromanometer:


Q: How do I perform zero adjustment on the 8715 DP-Calc Micromanometer?

A: Zero adjustment is handled automatically by the device through its auto-zeroing feature. This ensures accurate baseline measurements without manual intervention, allowing for more convenient and reliable operation.

Q: What is the process for logging and retrieving pressure data from this micromanometer?

A: Data logging is available with an optional upgrade and allows the storage of up to 12,700 samples. Data can be retrieved via the RS-232 serial interface for documentation and analysis on compatible systems.

Q: Where can the 8715 DP-Calc Micromanometer be used effectively?

A: This micromanometer is suitable for use in HVAC system commissioning, testing air flows in cleanrooms, labs, and industrial environments within the operating temperature range of 0C to 50C and up to 2,000 meters altitude.

Q: What benefits does the backlight and alarm features provide?

A: The LCD backlight ensures clear readings in low-light situations, while audible and visual configurable alarms promptly alert you to preset conditions, enhancing usability and operational safety.

Q: How long does the battery last, and what are the power options available?

A: Powered by four AA alkaline batteries, the 8715 DP-Calc offers up to 100 hours of operation. An optional AC adapter is also available for extended, stationary use.

Q: What types of units can the device display pressure measurements in?

A: The micromanometer supports a variety of pressure units, including Pascal (Pa), inches of water (in. H2O), millimeters of water (mm H2O), millibar (mbar), and psi, making it versatile for different measurement standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Micromanometer Category

5825 DP-Calc Micromanometer

5825 DP-Calc Micromanometer

Temperature Range : 0C to 50C (32F to 122F)

Power Supply : 9V Alkaline Battery

Display Type : Other, Digital LCD

Sensor Type : Piezoelectric Differential Pressure Sensor

Material : ABS Plastic

Flow Rate : Displays Calculated Airflow (requires optional pitot tube)

5815 DP-Calc Micromanometer

5815 DP-Calc Micromanometer

Temperature Range : 0 to 60C

Power Supply : 9V Alkaline battery

Display Type : Other, Dualline digital LCD

Sensor Type : Differential pressure sensor

Material : Highimpact plastic housing

Flow Rate : Calculated via optional pitot tube

HM675 Hydronic Manometer

HM675 Hydronic Manometer

Temperature Range : 32F to 122F (0C to 50C)

Power Supply : 9 V Alkaline battery

Display Type : Other, Large Digital LCD

Sensor Type : Sensor differential

Material : ABS plastic

Flow Rate : Displays Directly (with correct input)

HM685 Hydronic Manometer

HM685 Hydronic Manometer

Temperature Range : 0C to 50C

Power Supply : 9V Alkaline Battery

Display Type : Other, Digital LCD Display

Sensor Type : Differential Pressure Sensor

Material : ABS Plastic Housing

Flow Rate : Displayed (via Differential Pressure Calculations)



Back to top